Installer: Leave this manual with the appli-ance.Consumer: Retain this manual for future refer-ence.— Do not store or use gasoline or other flamma-bl
12429-10-0408Page 10FOR YOUR SAFETY READ BEFORE OPERATINGWARNING: If you do not follow these instructions exactly, a fire or explosion may result caus
12429-10-0408 Page 11CALL SERVICEMANSERVICE AND MAINTENANCE SUGGESTIONSGENERAL: All furnaces have been fire-tested to check for proper operation. Thi
12429-10-0408Page 12If the pilot does not light, or the pilot flame current is not at least 1.0 uA and steady, the module will not energize the second
12429-10-0408 Page 13Important 1. The following service procedures are provided as a general guide. 2. Meter readings between gas control and ig
12429-10-0408Page 14S8600H TROUBLESHOOTING GUIDE
Green LED Status CodesGreen LED Flash Code (X + Y)aIndicates Next System Action Recommended Service ActionOFF No “Call for Heat” Not applicable NoneFl
12429-10-0408Page 16PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 WFA-115 Baseplate
12429-10-0408 Page 17 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 PARTS VIEW
12429-10-0408Page 18Model No. FAW-55 may be vented as shown. The vent cap must be at least 12 feet (3.7m) above the floor. Clearance to combustible
12429-10-0408 Page 19SERVICE NOTES
12429-10-0408Page 2TABLE OF CONTENTSINTRODUCTION ...
12429-10-0408Page 20EMPIREEMPIREComfort SystemsEmpire Comfort Systems Inc.918 Freeburg Ave. Belleville, IL 62220If you have a general question about
12429-10-0408 Page 3IntroductionAlways consult your local Building Department regarding regulations, codes or ordinances which apply to the inst
12429-10-0408Page 4Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. You must find out if you
12429-10-0408 Page 5Ventilation and Combustion AirWall furnaces shall be installed in a location in which the facilities for ventilation permit satisf
12429-10-0408Page 6Figure 2 Figure 3 Figure 3AVENT CENTER TO COMBUSTIBLESMINIMUM CLEARANCE 9/16” (40mm)4”(102
12429-10-0408 Page 7Locating Furnace On WallThe furnace is to be located on a wall. The furnace is 16 inches (406mm) in width and norm
12429-10-0408Page 8Figure 6Electrode and pilot must be kept clean. Clean through pilot access hole with a small brush (toothbrush) and water.Proper M
12429-10-0408 Page 9Vent Safety Shutoff SystemThis appliance must be properly connected to a venting system. This appliance is equipped with a vent s